arv-tool-0.8(1)

manual page for arv-tool-0.8 0.8.23

Section 1 aravis-tools-cli bookworm source

Description

ARV-TOOL-0.8

NAME

arv-tool-0.8 - manual page for arv-tool-0.8 0.8.23

DESCRIPTION

Usage:

arv-tool-0.8 [OPTION?]

command <parameters>

Small utility for basic control of a Genicam device.

Help Options:

-h, --help

Show help options

Application Options:

-n, --name=<pattern>

-a, --address=<device_address>

--register-cache={disable|enable|debug}

Register cache policy

--range-check={disable|enable|debug}

Range check policy

--access-check={disable|enable}

Feature access check policy

-t, --time

Show execution time

-d, --debug={<category>[:<level>][,...]|help}

-v, --version

Show version

Command may be one of the following possibilities:
genicam:

dump the content of the Genicam xml data

features:

list all features

values:

list all available feature values

description [<feature>] ...:

show the full feature description

control <feature>[=<value>] ...:

read/write device features

network <setting>[=<value>]...:

read/write network settings

If no command is given, this utility will list all the available devices. For the control command, direct access to device registers is provided using a R[address] syntax in place of a feature name.