spotread(1)
Read Print Spot values.
Description
MEASURE
NAME
Measure - Read Print Spot values.
DESCRIPTION
Measure spot values, Version 1.6.3
SYNOPSIS
spotread [-options] [logfile]
|
-v |
Verbose mode |
|||
|
-s |
Print spectrum for each reading |
|||
|
-S |
Plot spectrum for each reading |
-c listno
Set communication port from the following list (default 1)
** No ports found **
|
-t |
Use transmission measurement mode |
|||
|
-e |
Use emissive measurement mode (absolute results) |
|||
|
-eb |
Use display white brightness relative measurement mode |
|||
|
-ew |
Use display white point relative chromatically adjusted mode |
|||
|
-p |
Use telephoto measurement mode (absolute results) |
|||
|
-pb |
Use projector white brightness relative measurement mode |
|||
|
-pw |
Use projector white point relative chromatically adjusted mode |
|||
|
-a |
Use ambient measurement mode (absolute results) |
|||
|
-f |
Use ambient flash measurement mode (absolute results) |
-I illum
Set simulated instrument illumination using FWA (def -i illum): M0, M1, M2, A, C, D50, D50M2, D65, F5, F8, F10 or file.sp]
-i illum
Choose illuminant for computation of CIE XYZ from spectral data & FWA: A, C, D50 (def.), D50M2, D65, F5, F8, F10 or file.sp
-Q observ
Choose CIE Observer for spectral data or CCSS instrument: 1931_2 (def), 1964_10, S&B 1955_2, shaw, J&V 1978_2 (Choose FWA during operation)
-F filter
Set filter configuration (if aplicable):
|
n |
None |
|||
|
p |
Polarising filter |
|||
|
6 |
D65 |
|||
|
u |
U.V. Cut |
-E extrafilterfile
Apply extra filter compensation file
|
-x |
Display Yxy instead of Lab |
|||
|
-h |
Display LCh instead of Lab |
|||
|
-V |
Show running average and std. devation from ref. |
|||
|
-T |
Display correlated color temperatures and CRI |
|||
|
-N |
Disable auto calibration of instrument |
|||
|
-H |
Start in high resolution spectrum mode (if available) |
-X file.ccmx
Apply Colorimeter Correction Matrix
-X file.ccss
Use Colorimeter Calibration Spectral Samples for calibration
-Y r|n
Override refresh, non-refresh display mode
-Y R:rate
Override measured refresh rate with rate Hz
|
-Y A |
Use non-adaptive integration time mode (if available). |
-W n|h|x
Override serial port flow control: n = none, h = HW, x = Xon/Xoff
-D [level]
Print debug diagnostics to stderr
logfile
Optional file to save reading results as text