waybar-temperature(5)
waybar - temperature module
Description
waybar-temperature
NAME
waybar - temperature module
DESCRIPTION
The temperature module displays the current temperature from a thermal zone.
CONFIGURATION
Addressed by temperature
thermal-zone:
|
typeof: integer | ||
|
The thermal zone, as in /sys/class/thermal/. |
hwmon-path:
|
typeof: string | |
|
The temperature path to use, e.g. /sys/class/hwmon/hwmon2/temp1_input instead of one in /sys/class/thermal/. |
hwmon-path-abs:
|
typeof: string | |
|
The path of the hwmon-directory of the device, e.g. /sys/devices/pci0000:00/0000:00:18.3/hwmon. (Note that the subdirectory hwmon/hwmon#, where # is a number is not part of the path!) Has to be used together with input-filename. |
input-filename:
|
typeof: string | |
|
The temperature filename of your hwmon-path-abs, e.g. temp1_input |
critical-threshold:
|
typeof: integer | |
|
The threshold before it is considered critical (Celsius). |
interval:
|
typeof: integer | |
|
default: 10 | |
|
The interval in which the information gets polled. |
format-critical:
|
typeof: string | |
|
The format to use when temperature is considered critical |
format:
|
typeof: string | |
|
default: {temperatureC}°C | |
|
The format (Celsius/Fahrenheit/Kelvin) in which the temperature should be displayed. |
format-icons:
|
typeof: array | |
|
Based on the current temperature (Celsius) and critical-threshold if available, the corresponding icon gets selected. The order is low to high. |
tooltip-format:
|
typeof: string | |
|
default: {temperatureC}°C | |
|
The format for the tooltip |
rotate:
|
typeof: integer | |
|
Positive value to rotate the text label. |
max-length:
|
typeof: integer | |
|
The maximum length in characters the module should display. |
min-length:
typeof: integer
The minimum length in characters the module should take
up.
align:
typeof: float
The alignment of the text, where 0 is left-aligned and 1 is
right-aligned. If the module is rotated, it will follow the
flow of the text.
on-click:
|
typeof: string | |
|
Command to execute when you clicked on the module. |
on-click-middle:
|
typeof: string | |
|
Command to execute when middle-clicked on the module using mousewheel. |
on-click-right:
|
typeof: string | |
|
Command to execute when you right clicked on the module. |
on-update:
|
typeof: string | |
|
Command to execute when the module is updated. |
on-scroll-up:
|
typeof: string | |
|
Command to execute when scrolling up on the module. |
on-scroll-down:
|
typeof: string | |
|
Command to execute when scrolling down on the module. |
smooth-scrolling-threshold:
|
typeof: double | |
|
Threshold to be used when scrolling. |
tooltip:
|
typeof: bool | |
|
default: true | |
|
Option to disable tooltip on hover. |
FORMAT REPLACEMENTS
{temperatureC}: Temperature in Celsius.
{temperatureF}: Temperature in Fahrenheit.
{temperatureK}: Temperature in Kelvin.
EXAMPLES
"temperature": {
|
// "thermal-zone": 2, | |
|
// "hwmon-path": "/sys/class/hwmon/hwmon2/temp1_input", | |
|
// "critical-threshold": 80, | |
|
// "format-critical": "{temperatureC}°C ï", | |
|
"format": "{temperatureC}°C ï" |
}
STYLE
•
#temperature
• #temperature.critical